Features and Benefits
- 6 DIs supporting PNP, NPN, and Dry contact
- 6 Form A relay output (Normal Open)
- Relay specification: 5A/250 VAC, 5A/30 VDC
- Instant event messaging by TCP/UDP/e-mail/SNMP trap
- DI and Relay counter saving when power off
- PC-based configuration utility and web console
- Power On default relay status setting with sequence
- Easy-to-use Click&Go™ Logic for local output control
- Windows/WinCE VB/VC and Linux C API
- I/O control over Modbus/TCP and SNMP protocol
Introduction
Remote Ethernet Relay Control
The ioLogik E2214 is a stand-alone Active Ethernet I/O product with 6 digital inputs and 6 relay outputs. The DIN-Rail mountable E2214 can be connected to digital switches, alarm lights, buzzers, and warning sirens over Ethernet and IP-based networks. The ioLogik E2214 is designed to record the counts of the usage of the build-in relay outputs. Even encountering the sudden power fail, the ioLogik E2214 is able to record the last counts into its internal storage before the power is fully down.
• LAN:
Ethernet 10/100Mbps, RJ45
Protection 1.5 KV magnetic isolation
Protocols Modbus/TCP, TCP/IP, UDP, DHCP, Bootp, SNMP (MIB for I/O and Network), HTTP, SNTP
• Serial:
Interface RS-485-2w: Data+, Data-, GND
Serial Line Protection 15 KV ESD for all signals
• Serial Communication Parameters:
Data Bits 8
Stop Bits 1
Parity None
Flow Control None
Protocols Modbus/RTU
Speed 1200 to 115200 bps
• Digital Input:
Channels 6 digital inputs
Sensor Type NPN, PNP, and Dry contact
I/O Mode DI or Event Counter (up to 900 Hz)
Dry Contact Logic 0: short to GND,
Logic 1: open
Wet Contact Logic 0: 0 to 3 VDC,
Logic 1: 10 to 30 VDC
Common Type 6 points/2 COM
Isolation 2K VDC or 3K Vrms
Counter Frequency 900 Hz
Digital Filtering Time Interval 10 ms
Over-voltage Protection 36 VDC
Relay Counter Saving Yes
• Digital Output:
Channels 6 Form A (N.O.) relay outputs, 5A
Contact Rating 5A @ 30 VDC, 5A @ 240 VAC, 5A @ 110 VAC
Inductance Load 2A
Resistance Load 5A
Breakdown Voltage 500 VAC
Relay On/Off Time 10 ms, 5 ms (Max.)
Initial Insulation Resistance 1G min. @ 500 VDC
Expected Life 100,000 times (Typical)
Initial Contact Resistance 30m ohms (Max.)
Pulse Output 20 operation times per minutes at rated load
Isolation 3K VDC or 2K Vrms
• Physical Characteristics:
Wiring I/O cable max. 14AWG
• Environmental Limits:
Operating Temperature -10 to 60°C (14 to 140°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
• Power Requirements:
Power Input 24 VDC nominal, 12 to 48 VDC
DO Power 24 VDC nominal, up to 30 VDC
• Agency Approvals:
EMI FCC Part 15, CISPR (EN55022) class A
EMS IEC 61000-4, IEC 61000-6
Shock IEC 60068-2-27
Freefall IEC 60068-2-32
Vibration IEC 60068-2-6
• Warranty:
Warranty Period 2 years
Details See www.moxa.com/warranty